LCexv 4010
Delivery in 15-20 Days
€2,431.00
VAT excluded
  • TAXES INCLUDED: €2,965.82

    Taxes calculated 22%. Pls. keep in mind, taxes vary by country: France taxes will be 20%, in Spain 21% etc., and if you are a company or out EU 0%

Atex 2014/34 / UE fridge-freezer; Temperatures 3...16°C/-9...-30°C; 4 trays and 3 drawers; digital control panel; alarms: under and over temperature, door open. 254/107 lt. Recommended use: Atex applications, laboratory, industry.

100% secure payments
 

Liebherr provides fridges and freezers with spark-free interiors especially for storing explosive and highly flammable substances in labs and in the chemical industry. The inner liners meet the safety requirements of the EU Directive 2014/34/EU (ATEX) and have been tested according to the EN 1127-1, IEC 60079-0 and IEC 60079-15 standards by elecosuisse – SEV (Swiss Association for Electrical Engineering, Power and Information Technologies), an approved ATEX conformity evaluation organisation

The electronic controller
The precise electronic controller with digital temperature display enables temperatures to be set accurately to 0,1°C. Symbols indicate the operating status of the appliance. The electronic controller is flush-mounted and equipped with a membrane keyboard for perfect hygiene. The large display allows improved temperature visibility at a glance. Plus, it is equipped with an integrated data memory which logs the maximum and minimum internal temperatures as well as the last three temperature alarms and power failures, together with the time, date and duration. These data can be read out on the display

Integrated alarm systems
Visual and audible alarm systems alert the user to undesired temperature deviations or when the door is open. All alarm parameters can be individually set. For example, the door- open alarm delay can be adjusted between 1 and 5 minutes. Furthermore, the laboratory appliances with electronic controls have a visual power failure alarm and a sensor defect alarm

External temperature and alarm documentation
The laboratory appliances are equipped with a volt-free contact for alarm forwarding to an external remote warning system, as well as with a serial interface RS 485 which enables central documentation of temperature profiles and alarm events. LTM monitoring software is optionally available

Sturdy glass shelves
The sturdy glass shelves are easily adjustable in height and can conveniently be removed at a door opening angle of 90°. They ensure secure positioning of the refrigerated or frozen products and have a loading capacity of up to 40 kg in the refrigerator compartment and up to 24 kg in the freezer compartment. External temperature sensor. The laboratory appliances with electronic controls have an access port (diameter 10 mm) on the rear which allows the temperature sensor to be positioned in the interior.

Safety and maximum temperature consistency
Maximum temperature stability is ensured by the cooling systems of the laboratory fridges and freezers in conjunction with the electronic controller. The fridges are equipped with a safety thermostat to prevent temperatures below +2°C in case of a fault. All laboratory appliances with electronic controls are designed according to the EN 60068-3 standard with regard to maximum temperature stability and consistency

control panel LCexv 4010 Liebherr

 

 

 

 

 

Adjustable temperatures (°C)
+3°C...+8°C / -30°C...-9°C
Inner Gross/Net Capacity Liters
361 (254 liters fridge; 107 liters freezer)
Freezer Storage Gross/Net Volume
107
Exterior Dimensions mm WxDxH
601 / 618 / 2003
Inner Dimensions mm WxDxH
440 / 441 / 1105; 433 / 433 / 597
Shelves / Baskets
4
Drawers
3
Control Panel
Digital Display
Open door alarm
Yes
Power Failure Alarm
As an option
Visual and acoustic temperature alarm
Yes - Min. & Max temperature
Adjustable alarms
Yes
Dry Contact
Yes
Max Ambient Temp. to reach the Min. Temperature
35
Data logger
As an option
RS 485 Interface
Yes
Lock
Yes
Defrost
Automatic
Porthole for PT 100
As an option
Refrigeration technology
Double Compressor
Noise level (db)
52
Refrigerant
R600a
Climate Class
SN-ST
Energy consumption [kWh/24h]
1,8
Connection rating (A)
1,5
Supply Voltage (V) / Frequency (Hz)
220 - 240 / 50
Weight kg
87
Various
Memorizzazione max e min temperatura e allarmi, porta con cerniera a destra reversibile, direttiva UE 94/9/CE (ATEX 95)
Warranty
Liebherr International warranty 24 months