Refrigerator for universal use; 141 l; adjustable temperature from 2°C to 15°C; 3 shelves; alarms: under and over temperature, door open and power failure; lockable door. Suggested use: universal.
10 Items
In Stock
Adjustable temperatures (°C) | 1°C...15°C |
Exterior Dimensions mm WxDxH | 600x620x820 |
Inner Dimensions mm WxDxH | 440x440x670 |
Inner Gross/Net Capacity Liters | 141 |
Shelves / Baskets | 3 |
Inner Fan | Yes, disconnectable |
Control Panel | Display LCD |
Open door alarm | Yes |
Power Failure Alarm | Yes - it last about 12 hrs. |
Visual and acoustic temperature alarm | Yes - Min. & Max temperature |
Adjustable alarms | As an option |
Max Ambient Temp. to reach the Min. Temperature | 43 |
Data logger | As an option |
Lock | Yes |
Defrost | Automatic |
Porthole for PT 100 | As an option |
Refrigeration technology | Compressor |
Insulation mm | 40 |
Noise level (db) | 45 |
Refrigerant | R600a |
Climate Class | SN-ST |
Max Power Input (W) | 240 |
Energy consumption [kWh/24h] | 0,7 |
Connection rating (A) | 1 |
Supply Voltage (V) / Frequency (Hz) | 220 - 240 / 50 |
Weight kg | 38 |
Comply with Italian Republic Farmacopea Ufficiale XII edizione Tabella VI | Yes, with the use of data logger to be purchased from the options, if you not have already one: e.g. this: http://www.frigolab.it/it/dataloggers/312-new-datapoint-16n.html |
Various | Sicurezza blocco tasti, ventilato, porta con cerniera a destra reversibile, chiusura porta automatica |
Warranty | International Warranty 24 months only for spare parts. |
Refrigerators efficient and in compliance with the pharmacopoeia. The backlit LCD display constantly monitors the internal temperature and reports any alarms over and under temperature if should they persist.
Refrigerators powerful and well insulated because suitable for ambient temperatures from 10 ° C to 43 ° C; housing in white painted steel; internal space in PS.
Technical equipment:
LCD (Liquid Crystal Display) with adjustable brightness
Low and high temperature alarms and door open;
Alarm blackout;
Safety key lock;
ventilated;
Automatic defrosting;
Lock;
Reversible door with right hinge;
Automatic door locking
glass door
Internal LED light
VJT 2721e Test
Tests with a control probe in liquid. Red line = room temperature; green line = temperature in the medium.
Set: 5 ° C.
The test shows a rapid drop in temperature to reach 5 ° C (in the sample) in 75 min.; the temperature stabilizes between 4.4 and 4.6 ° C with no major shifts.
Test is generic with a datalogger not certified but still subjected to comparison with certified thermometer in our laboratories. The behavior is typical of a VJT 2723, but is not representative of the entire production. The accuracies may vary from model to model and depending on the thermal differences and load.